WRM-10P AND WRM-40 USER’S MANUAL REV 3
10
2.0 PRE-TEST SETUP
2.1 Operating Voltages
The WRM’s operating voltage is preset at the factory and is selectable between 100-120 Vac,
50/60 Hz or 200-240 Vac, 50/60 Hz. The voltage is set by placing jumper(s) on the power
terminal block as listed in Table 5 and illustrated in Figure 3 and Figure 4. The relay must also be
changed if the voltage settings are changed. Please see Figure 5 and Figure 6 for the location of
the relays.
Table 5. Voltage Selection Jumper Settings
Voltage
Selection
Terminal Block Jumpers
Relay
Part Number
100
120 Vac
Brown to Blue and Yellow to Green HE2aN-Q-AC120V
200
240 Vac
Blue to Yellow HE2aN-Q-AC-240V
Figure 3. 100 – 120 Vac Jumper Settings
Figure 4. 200 – 240 Vac Jumper Settings